products:promonitor:latest:monitorsguide:netweaver:abaprda
Table of Contents
SAP ABAP Real-Time Data Acquisition Monitoring
This monitor supervises ABAP Real-Time Data Acquisition (RDA) errors and failed RDA requests, with threshold-based alarms and optional time-series metrics.
What Can Be Monitored
You can detect and alert on:
- RDA processing errors
- Failed RDA requests
- Error bursts over configurable time windows
This supports proactive detection of blocked or degraded RDA data loading flows.
Configuration Hints
- One surveillance row defines one threshold rule and one evaluation window.
- `Period (min) = 0` means “since last monitor execution”.
- `Max errors = 0` disables alarm checks for that row.
- Metric sends only the “RDA errors” metric (not request-error count).
- Prefix is applied to alarm text and used as alarm tag.
- Category is available in configuration but not used as a filter by current evaluation logic.
- Report is used only when monitor runs in report mode.
Configuration
Monitoring Parameters
This monitor has no global monitoring parameter. All settings are defined in the surveillance table.
Surveillance Table
| Field | Required | Default | Description |
|---|---|---|---|
| Active | Yes | 'true' | Enables/disables this surveillance row. |
| Category | Yes | `*` | Logical category label for the row. |
| Max errors | Yes | `INFO` | Threshold expression for alarms. Alarm when computed count is greater than or equal to threshold. |
| Severity | Yes | `MAJOR` | Alarm severity used when threshold is breached. |
| Period (min) | Yes | `0` | Evaluation window in minutes. `0` means since last monitor execution. |
| Auto clear | Yes | `true` | Alarms generated by this row are clearable when condition recovers. |
| Prefix | No | (empty) | Optional alarm prefix and alarm tag value. |
| Alarm | No | `true` | Enables/disables alarm generation for this row. |
| Metric | No | `false` | Enables/disables metric emission for RDA error count. |
| Report | No | `false` | Enables report flagging when monitor runs in report mode. |
Alarm Conditions
For each active surveillance row:
- RDA errors alarm: triggered when `sum(COUNT_FAILS in window) >= Max errors`
- RDA request errors alarm: triggered when `count(requests in error in window) >= Max errors`
Additional behavior:
- If `Max errors = 0`, alarm checks are skipped for that row.
- If Alarm is disabled, no alarms are generated.
- Alarm message time window uses `Period (min)` or computed “since last check” duration when period is `0`.
Generated Metrics
If Metric is enabled, the monitor emits:
| Metric | Unit | Description |
|---|---|---|
| RDA errors count | Errors | Sum of `COUNT_FAILS` from `RSCRT_RDA_ERROR` over the evaluated window. |
Generated Alarms
Alarm messages include evaluated count and threshold, for example:
- `X RDA errors in last P min (>=Y)`
- `X RDA request(s) in error in last P min (>=Y)`
If Prefix is set, it is applied to alarm messages.
Example
| Active | Category | Max errors | Severity | Period (min) | Auto clear | Prefix | Alarm | Metric | Report |
|---|---|---|---|---|---|---|---|---|---|
| true | `*` | `1` | 4 | 15 | true | `RDA` | true | true | false |
| true | `FIN_*` | `G2W:5` | 3 | 0 | true | `BW,RDA` | true | false | false |